Pulp and Paper Mill Sample Probes — Black Liquor, White Liquor, and Bleach Plant

Sample probes for kraft pulp mills: black liquor, white liquor, green liquor, bleach plant chlorine dioxide, and recovery boiler sampling. Material selection for caustic and oxidizing chloride service.

Overview

Pulp and paper mills cycle through nearly every aggressive process chemistry: hot caustic (white liquor), oxidizing chlorides (bleach plant), reducing sulfides (green liquor), and high-temperature combustion gas (recovery boiler). Sample probes must be matched to the specific stage of the kraft cycle.

Stage-by-Stage

StageServiceMaterial

Wood prep, chip washWater + bark316L
DigesterHot white liquor (NaOH + Na2S)316L or duplex
Brown stock washerWeak black liquor316L
EvaporatorsConcentrating black liquor316L; duplex above 50% solids
Recovery boilerSmelt, hot flue gasInconel 625
Causticizing (green liquor)Na2S + Na2CO3316L
White liquor clarifierNaOH + Na2S316L
Bleach plant — D stage (ClO2)ClO2 + Cl-Hastelloy C276
Bleach plant — E stage (NaOH)NaOH316L or duplex
Bleach plant — P stage (peroxide)H2O2316L

The Bleach Plant Problem

Chlorine dioxide bleach (ClO2) at 50-70 °C is one of the most aggressive industrial chloride environments. Free Cl⁻ at concentrations of several thousand ppm combined with the strong oxidizing action of ClO2 destroys 316L by chloride pitting within weeks.

The standard answer is Hastelloy C276, which combines the chloride resistance of 16% Mo + 4% W with the oxidation resistance of 16% Cr. For the most severe service, C22 or titanium grade 7 is specified.

Recovery Boiler

The recovery boiler burns concentrated black liquor and recovers sodium sulfate as smelt. Sample probes in the flue gas path see 1500-2000 °F combustion products with sulfur and sodium compounds. Inconel 625 is the standard material.

Configurator Defaults

When the user selects "pulp and paper" in the SPA Configurator:

1. The material recommender asks which stage of the kraft cycle

2. Bleach plant defaults to Hastelloy C276

3. Recovery boiler defaults to Inconel 625

4. Caustic service defaults to 316L with high-temperature derating